datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent MAC Mode Imaging of Biological Molecules with 7500 AFM - Application Note 5991-3672EN c20141020 [2]

Agilent MAC Mode Imaging of Biological Molecules with 7500 AFM - Application Note 5991-3672EN c20141020 [2] free download

Various electronics service manuals

File information:
File name:MAC Mode Imaging of Biological Molecules with 7500 AFM - Application Note 5991-3672EN c20141020 [2].
[preview MAC Mode Imaging of Biological Molecules with 7500 AFM - Application Note 5991-3672EN c20141020 [2]]
Size:108 kB
Extension:pdf
Mfg:Agilent
Model:MAC Mode Imaging of Biological Molecules with 7500 AFM - Application Note 5991-3672EN c20141020 [2] 🔎
Original:MAC Mode Imaging of Biological Molecules with 7500 AFM - Application Note 5991-3672EN c20141020 [2] 🔎
Descr: Agilent MAC Mode Imaging of Biological Molecules with 7500 AFM - Application Note 5991-3672EN c20141020 [2].pdf
Group:Electronics > Other
Uploaded:13-08-2021
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name MAC Mode Imaging of Biological Molecules with 7500 AFM - Application Note 5991-3672EN c20141020 [2].

Keysight Technologies MAC Mode Imaging of Biological Molecules with Keysight 7500 AFM Application Brief Introduction examples of high-resolution MAC mode imaging of biological samples in liquid One of the most appealing features of using Keysight 7500 AFM will atomic force microscopy (AFM) for the be demonstrated. field of biology is that it can operate in aqueous environments, making this Instrumentation technique capable of monitoring or measuring biological molecules under The Keysight 7500 AFM/SPM physiological conditions. In terms of microscope is a high-performance AFM imaging, the complexity of probe instrument that delivers high resolution oscillations and tip/sample force imaging with integrated environmental interactions in solutions is much higher control functions. Keysight's patented than that under ambient conditions. For magnetic AC mode (MAC Mode) is Figure 1. MAC mode imaging of lambda phage instance, ordering of the liquid at a solid offered as a system option. Switching DNA in a buffer solution. interface is a ubiquitous phenomenon imaging modes with the Keysight and such liquid structuring could have a profound effect on the operation of an 7500 AFM/SPM microscope is quick Imaging of DNA in and convenient, a result from the AFM, causing the tip to hop between scanner's interchangeable, easy- a Buffer Solution different stable configurations in the to-load nose cones. Every aspect of ordered region of the fluid. A Keysight the Keysight 7500 AFM's design and Lambda phase DNA is used as the first Technologies, Inc. patented magnetic construction are optimized to reduce example to demonstrate the effective AC (MAC) mode is developed as a better mechanical noise, and deliver industry AFM imaging in liquid. When DNA in a approach to AFM in liquid, in which only leading performance. The compact buffer solution containing Ni++ or Mg++ the cantilever part of an AFM probe is and completely encapsulated scanner is added to a mica substrate, these coated with a thin magnetic coating provides easy cantilever exchange, a divalent cations can form a charge and the introduction of an alternating slot for (optional) preamps for STM bridge between the negatively charged magnetic field will induce a direct tip and CSAFM operation, as well as an phosphate groups on the DNA backbone oscillation. This method eliminates integrated, high-reliability connector to and the negatively charged siloxy groups the spurious resonances seen in fluid interface with the control electronics. on the mica. This



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : DENON hfe denon dtr-2000 service en

script execution: 0.07 s